Radio Nurse Call, Wireless Nurse Call
The Aid Call Nurse Call System is a radio based call system, allowing patient to alert nursing staff. The components are designed to be aesthetically pleasing and give patients and residents the maximum independance. It ensures that the highest level of care can be provided with efficient staffing levels.
As the system is wireless, installation is very quick, easy and can be completed with minimal disruption. the system is easily expandable
The heart of the system is one of two newly developed call processor panels. Once a control panel is selected room units, and other accessories can be added to build up a complete system.
Components
CP3400 The CP3400 control panel offers a large LED display of four characters – the red character identifying the call type or zone and the yellow characters the room or bed, with a first call alerted by two green LEDS.
Four selectable alarm tones identify call, assist, emergency and fault. Up to 10 multiple zones can be programmed for each panel, An optional call logger can be built in, automatically recording the history of up to 50,000 call events
CP3500The 15" TFT flat screen can display text addresses for call types, locations, resident/patient names, active call list and staff location together with optional floor plan/map.
The status of calls is displayed and more information can be requested where necessary, for example, brief patient medical notes can be called up.
Four selectable alarm tones identify call, assist, emergency and fault.
Up to 10 zones can be programmed for each panel, plus an optional call logger can be built in automatically recording the history of the call events

ATX3000 The ATX 3000 room units come complete with pull cord and 2 sockets for pear push leads or auxiliary trigger devices which include an optional cradle and pear push lead.
The ATX3000 has a built-in infra red receiver that enables it to be remotely activated using the "Buddy" infra red transmitter.
Call types - Call, Assistance, Emergency, Cancel, Low Battery and Fault, Nurse Presence (optional)
Power supply - 4 x alkaline AA batteries
Accessories
Staff Attack Location alarm
 The system, can be expanded into a staff attack system with the use of a Buddy infra red transmitter. When activated, the Buddy transmits an alrm code and call type to the ATX3000
There are three modes of operation
- A push button alarm
- A pull switch alarm, anti tamper device
- A push button cancel - selectable
Call Logging Call logging software is available to
Alternatively, call can be captured on a printer
Other accessories available for use with the systems are :
- Pear Push Leads
- Remote Ceiling Pullcord
- Overdoor lights
- Bed Weight Sensor
- Chair Sensor
- Pagers
- Door Monitoring
- PIR Movement Sensor
- Telephone Ring Detector
|