GD Systems - Creating Safer Environments
Fire Systems
Healthcare Systems
Security Systems
Automation Systems

GD Systems fire
Fire detection systems
Conventional fire alarms
Analogue addressable alarms
Wireless fire alarms
Alarm monitoring
Fire risk assessment
Emergency lighting
GD Systems healthcare
Call systems
Staff attack / location
Quantec call system
Infra-red staff attack
Aid Call wireless nurse call
Spider Alert
Pagers
DDA
Deaf alarms / alerting
Induction loop equipment
GD Systems security
Security Fencing
Salto Lock Management
Salto Range of Locks
CCTV - Axis Network Video
CCTV - Axis Network Video Products
Access Control
Salto Access Technologies
Paxton Access
CCTV
Video Entry
Lone Worker Protection and Man Down
Impact
Identicom
GD Systems auto
Plant Monitoring
M & T
M2M

Conventional Fire Alarms

Fire Alarm Systems - Conventional Fire Alarms

Conventional Fire Alarms have been around for many years and the technology has changed little in that time although design and reliability have improved significantly. Conventional fire alarms are a well-proven as established technology protecting many hundreds of thousands of properties worldwide.

A Conventional Fire Alarm System is often the natural choice for smaller systems or where budget constraints exist as these can be cost effective, typical installations are to be found in shops and offices.

In a typical Conventional Fire Alarm System, if a trigger is received from a detector or manual call point, the Fire Alarm Control Panel signals the condition to other devices such as alarm sounders and remote signalling equipment

Conventional fire detectors are normally connected to the Fire Control Panel via dedicated circuits, each circuit protecting a designated 'Zone' or 'Area' of the building (the maximum size of which will often be governed by local standards). Detectors have two states, Normal healthy and Alarm.

The Fire Control Panel will normally be arranged in a set number of Zones or Circuits e.g. 1, 2, 4, 8 etc. and have 2 separate sounder circuits.



CFP 2-8 Zone Conventional Fire Alarm Control Panel


The CFP two-wire fire panel is designed to work with Apollo's AlarmSenseŽ range of detectors, call points and sounders.

Most conventional fire alarm systems are designed to work with two pairs of wires per zone: one pair for detection devices such as smoke detectors, heat detectors and manual call points; the other for alarm devices such as bells, sounders or strobes. By using different voltage bands for quiescent and alarm states, AlarmSenseŽ components can be connected to the same pair of supply wires.

When powered and controlled by the CFP two-wire fire panel, this reliable technology takes all the complexity out of fire alarm systems design, leading to quicker, less expensive and more flexible installation.

  • Designed to comply with EN54 parts 2 and 4.
  • Available with 2, 4 or 8 AlarmSenseŽ zone circuits (dependent on model purchased).
  • Installer-friendly design accommodates easy first fix and straightforward maintenance.
  • Attractive flush or surface mountable plastic lid and enclosure.
  • Auxiliary remote, fire, fault and reset outputs.
  • 'Class change' and alert inputs.
  • Four conventional sounder circuits (for use with non-AlarmsenseŽ sounders).
  • Low quiescent current - for extended standby times with small batteries.
  • Intuitive user-friendly interface.
  • Multiple indicators provide a comprehensive overview of system status.
  • Push button access code or keyswitch entry (dependent on model purchased) to a wide range of Engineering functions, including:-
    • Selectable zone delay facility
    • Zone test facility
    • Coincidence (double-knock) facility
    • Non-latching zones facility
    • Comprehensive fault diagnostic facilities
  • System expansion connections for up to eight two-wire repeater panels and a range of Relay Output Cards

User Manual >>

 